1, the elevator machine room environment should be clean, room doors and windows should be weatherproof and marked with "Machine Room, trespassers", leading to the room of the channel should be smooth, safe and other equipment room should be independent from the lift;

2, room power board and power switch should meet the specification requirements, installation position is reasonable, firm, marking perfect, room line slot laying should be reasonable, standard;

3, the power line and control line isolation laying the corner with rest pad;

4, room ventilation is good, room temperature should be maintained between 5 ~ 40 degrees, the computer room should have fixed trial electrical lighting, floor surface lighting degree is not less than 200LX;

5, there should be room for emergency equipment and instructions;

6, elevator hoistway and machine room hole, lead rope flat layer mark, elevator running direction mark should meet the specification requirements;

7, the computer room control cabinet is installed correctly, the control cabinet is installed correctly, the control cabinet walks the line reasonable, artistic;

8, the room should have the necessary fire equipment.